Masking Enhances Accuracy of Bladder Deformation in Multi-Fraction Adaptive Brachytherapy as a First Step Toward Composite Dose Estimation

dc.contributor.otherAlbuquerque, Kevinen
dc.contributor.otherPompos, Arnolden
dc.contributor.otherGu, Xuejunen
dc.creatorBarclay, Jenniferen
dc.date.accessioned2015-07-08T12:57:13Z
dc.date.available2015-07-08T12:57:13Z
dc.date.issued2014-02-04
dc.descriptionThe 52nd Annual Medical Student Research Forum at UT Southwestern Medical Center (Tuesday, February 4, 2014, 3-6 p.m., D1.502)en
dc.description.abstractBACKGROUND: GEC-ESTRO guidelines for cervix HDR brachytherapy advocate measurement of the minimum dose to the 2cc volume of organs at risk (OAR) receiving the highest amount of radiation and summation across multiple treatment fractions to give a worst-case-scenario cumulative dose estimate. If the OAR from different fractions could be accurately co-registered using deformation, then a more accurate composite dose could be obtained. OBJECTIVE: As a first step toward composite dose estimation, we sought to assess and improve the quality of bladder deformation using a technique called masking, which involves resetting the pixel values within a contour. METHODS: CT scans from nine cervical cancer patients with bladders contoured by radiation oncologists were obtained, and the urethra near the bladder was contoured using the catheter as a fixed reference point. Three copies of each CT were made: the first was unaltered, the second had the bladder masked, and the third had the bladder masked at one pixel value and the rest of the body masked at a different pixel value. Using VelocityAI 2.8.1, the bladder was deformed onto the target (Fraction 1) planning CT from subsequent planning CTs in an attempt to match up the tissue from different fractions. To assess the accuracy of the deformation, several indices were used: the percent error of the deformed bladder volume from the expected volume, the conformality index, the Hausdorff distance, and the distance between the centers of the deformed urethra and the target urethra. RESULTS: Deformation quality improved with masking. The standard deviation of the percent error was reduced from 18.1% with no masking to 4.3% with masking. Mean conformality increased from 0.83 with no masking, to 0.91 with the bladder masked, to 0.93 with body and bladder masked (P<0.001). The mean Hausdorff distance decreased from 13.8mm without masking, to 9.1mm with the bladder masked, to 5.7mm with body and bladder masked (P<0.001). The mean error in the urethra deformation increased from 4.3mm without masking, to 5.2mm with the bladder masked, to 6.6mm with body and bladder masked (P=0.08). CONCLUSION: The accuracy of bladder deformation can be significantly improved by masking. With masking, the volume and location of the deformed bladder more closely approached that of the target bladder than without masking. Thus masking has the potential to improve the accuracy of dose deformation and composite dose calculation in adaptive brachytherapy.en
dc.description.sponsorshipSouthwestern Medical Foundationen
dc.identifier.citationBarclay, J., Albuquerque, K., Pompos, A., & Gu, X. (2014, February 4). Masking enhances accuracy of bladder deformation in multi-fraction adaptive brachytherapy as a first step toward composite dose estimation. Poster session presented at the 52nd Annual Medical Student Research Forum, Dallas, TX. Retrieved from https://hdl.handle.net/2152.5/1655en
dc.identifier.urihttps://hdl.handle.net/2152.5/1655
dc.language.isoenen
dc.relation.ispartofseries52nd Annual Medical Student Research Forumen
dc.subjectClinical Research and Case Reportsen
dc.subject.meshBrachytherapyen
dc.subject.meshOrgans at Risken
dc.subject.meshRadiation Monitoringen
dc.subject.meshTomography, X-Ray Computeden
dc.subject.meshUrinary Bladderen
dc.subject.meshUterine Cervical Neoplasmsen
dc.titleMasking Enhances Accuracy of Bladder Deformation in Multi-Fraction Adaptive Brachytherapy as a First Step Toward Composite Dose Estimationen
dc.typePresentationen

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Barclay UTSW Research Forum Poster.pdf
Size:
915.35 KB
Format:
Adobe Portable Document Format
Description:
PDF--public access

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
297 B
Format:
Item-specific license agreed upon to submission
Description: