Moving Phantom Study of Stereotactic Body Radiation Therapy for Lung Cancer

dc.contributor.advisorPapiez, Lechen
dc.creatorHuang, Longen
dc.date.accessioned2011-02-01T19:34:50Z
dc.date.available2011-02-01T19:34:50Z
dc.date.issued2011-02-01
dc.description.abstractTo assess the accuracy of current stereotactic body radiation therapy (SBRT) lung treatment methodologies, we performed a systematic evaluation using phantoms that simulated motions from real patients (irregular motions) as well as sinusoidal motions (regular motions). The irregular patterns investigated in this study were of two types: small range irregular breathing motions (=10mm) and large range irregular breathing motions (=20mm). Four-dimensional computed tomography (4DCT) and cone beam computed tomography (CBCT) are important methodologies for SBRT, but previously have only been used to evaluate regular patterns. For targets moving regularly or irregularly within a small range (7.0 ± 1.8 mm, n = 6), we observed good agreement between the measured and computed dose distributions. However, for targets moving irregularly with a larger range (20.8 ± 2.6 mm, n = 4), the measured isodose lines were found to be shifted relative to the planned distribution, resulting in an underdosing (over 20%) in a portion of the PTV. In this underdosed volume, 1-2% of the PTV is underdosed by over 18 Gy, causing a 35-40% drop in the local control rate. We further observed that the discrepancy between the planned and measured dose distribution was due to the inaccurate representation of the irregular target motion in the maximum intensity projection (MIP) images generated from 4DCT, which could not be corrected by CBCT. A method of Extended Distance Virtual Isocenter (EDVI) was developed to lower the toxicity of healthy tissues. In all, caution should be used when planning from 4DCT images in the presence of large and irregular target motion. The inaccuracy inherent in 4DCT MIP and CBCT images can be mitigated through the application of methodologies to reduce respiratory motion, such as abdominal compression, and through the use of volumetric image guidance to assure precise targeting with minimal shifts.en
dc.identifier.oclc719515070
dc.identifier.urihttps://hdl.handle.net/2152.5/850
dc.language.isoenen
dc.subjectRadiosurgeryen
dc.subjectFour-Dimensional Computed Tomographyen
dc.subjectLung Neoplasmsen
dc.subjectPhantoms, Imagingen
dc.titleMoving Phantom Study of Stereotactic Body Radiation Therapy for Lung Canceren
dc.typeThesisen
dc.type.materialTexten
thesis.date.available2013-01-26
thesis.degree.departmentGraduate School of Biomedical Sciencesen
thesis.degree.disciplineRadiological Sciencesen
thesis.degree.grantorUT Southwestern Medical Centeren
thesis.degree.levelDoctoralen
thesis.degree.nameDoctor of Philosophyen

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
938 B
Format:
Item-specific license agreed upon to submission
Description: