Motion Estimation and Motion-Compensated Reconstruction for Four-Dimensional Cone Beam Computed Tomography (4D-CBCT)

dc.contributor.advisorJia, Xunen
dc.contributor.committeeMemberWang, Jingen
dc.contributor.committeeMemberSun, Xiankaien
dc.contributor.committeeMemberJiang, Steve B.en
dc.creatorHuang, Xiaokunen
dc.creator.orcid0000-0002-1156-5539
dc.date.accessioned2022-06-22T22:02:59Z
dc.date.available2022-06-22T22:02:59Z
dc.date.created2020-05
dc.date.issued2020-05-01T05:00:00.000Z
dc.date.submittedMay 2020
dc.date.updated2022-06-22T22:03:00Z
dc.description.abstractThe emerging of sophisticated radiation therapy such as stereotactic body radiation therapy (SBRT) characterizing as high dose in each fraction and few fraction number requires higher accuracy for tumor localization. For organs influenced by the respiration, respiration induced motion becomes the principal cause for tumor localization uncertainty and four dimensional (4D) cone beam computed tomography (CBCT) has been developed to locate tumor in each respiration phase to better estimate the possible motion range of the tumor motion during the treatment. However, 4D-CBCT reconstructed by conventional methods on current commercial scanners is not optimal for tumor localization due to low image quality caused by insufficient number of projections located in each phase after the projection binning according to respiration phases. The specific aims of this dissertation research are to: 1) improving the accuracy of inter-phase motion model to feed in a motion-compensated reconstruction scheme to improve the 4D-CBCT image quality; 2) utilizing high-quality 4D-CBCT for motion evaluation and 4D dose accumulation for lung cancer patients receiving SBRT. The motion-compensated reconstruction suppresses motion and improves image quality by deforming other phase image to the reference phase using inter-phase motion model to reconstruct reference phase image using projections from all phases. Therefore, it is essential to improve the inter-phase motion model accuracy. Two methods, biomechanical modeling based and convolutional neural network (CNN) based, were applied to fine-tune the inner lung motion model. The biomechanical modeling is a physics-driven method which introduced tissue related elasticity properties to simulate the movement of lung and solve the deformation by finite-element analysis. Biomechanical modeling requires boundary condition which is the deformation vector fields (DVFs) estimated from a 2D-3D registration. For CNN based methods, boundary DVFs are also used as the input for the U-net based architectures to predict the inner lung motion. All methods can improve accuracy of DVFs and further improve reconstructed 4D-CBCT images quality. After obtaining high-quality 4D-CBCT images, we created a tool using 4D-CBCT images to evaluate the motion variation as well as calculate the accumulated 4D dose to monitor and evaluate the delivered dose for lung SBRT patients.en
dc.format.mimetypeapplication/pdfen
dc.identifier.oclc1333220194
dc.identifier.urihttps://hdl.handle.net/2152.5/9869
dc.language.isoenen
dc.subjectCone-Beam Computed Tomographyen
dc.subjectFour-Dimensional Computed Tomographyen
dc.subjectImage Processing, Computer-Assisteden
dc.subjectMovementen
dc.subjectOrgan Motionen
dc.titleMotion Estimation and Motion-Compensated Reconstruction for Four-Dimensional Cone Beam Computed Tomography (4D-CBCT)en
dc.typeThesisen
dc.type.materialtexten
thesis.degree.departmentGraduate School of Biomedical Sciencesen
thesis.degree.disciplineBiomedical Engineeringen
thesis.degree.grantorUT Southwestern Medical Centeren
thesis.degree.levelDoctoralen
thesis.degree.nameDoctor of Philosophyen

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
HUANG-PRIMARY-2022-1.pdf
Size:
4.01 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
LICENSE.txt
Size:
1.84 KB
Format:
Plain Text
Description: